  ËÁÇ´ÊÔ¹¤éÒ Monitoring Modules

Phase sequence relay BA 9041, AI 941 N

• According to IEC 255, EN 60 255, VDE 0435 part 303
• Detection pof wrong phase sequence
• 1 or 2 changeover contacts
Width 45 mm.
 

                                                                                             ÃÒÂÅÐàÍÕ´

Asymmetry realy BA9042,AI942

• According to IEC 255, VDE 0435 part 303
• For nominal voltage from 3 AC 230 V to 500
• Detection of
  - voltage asymmetry
  -
wrong phase sequence
  - phase failure

• Detection of feedback voltage
BA 9042 optionally with ajdustable time delay
• Closed circuit operation
• BA 9042 LED indicators for operation and state of cantacts
• 2 LED displays for power supply and state of contact
Width 45 mm
Standard Type: BA 9042 3 AC 400V 50/60 Hz

Article number: 0040770
stock item
- Output: 2 changeover contacts

- Nominal voltage UN: 3 AC 400

- Output: 2 changeover contacts
-
Nominal voltage UN: 3 AC 400V
- Width: 45 mm
 

                                                                                             ÃÒÂÅÐàÍÕ´

Under voltage  realy BA9043,AA9943

• According to IEC 255, VDE 0435 part 303
• 3-phase
• For nominal voltage of 3 AC 100/57 to 690/400V
• Measures arithmetic mean value
• Adiustable operate and release value
• For  3p3w or 3p4w systems
• BA 9043 optionally with adiustable time delay
Closed circuit operation
• LED indicator for operation and state of contact
• Insensitive to hermonics
• Frequency up to 400 Hz
Width 45 mm
                                                                                             ÃÒÂÅÐàÍÕ´

Thermistor motor protection relay BA9038, AI938

• According to DIN VDE 0660 part 302 ( pr EN 60 947-8 )
  and part 303
• 1 input for PTC-resistors or bimetal contacts
• Broken wire dtdection in sensor ciruit
• Optionally with no voltage reclosing interlock
• Closed circuit operation
• 1 or 2 changeover contacts
Width 45 mm
                                                                                            ÃÒÂÅÐàÍÕ´

Current relay BA 9053, MK 9053

• According to IEC 255, EN 60 255, VDE 0435 part 303
• to: monitor DC and AC
• Measuring ranges from 2 ma to  25 A
• BA 9053 with galvanic separated DC auxiliary supplay
• High overload possible
• Input frequency up to 5 kHz
• with time delay, up to max. 100 sec
BA 9053 optionally with 3 current ranges 0,1 to 25A
• BA 9053 optionally with safe separation to IEC/EN 61 140
  IEC/EN 60 947-1

• BA 9053 as option with start - up delay
• BA 9053 as option with manual reset
• MK 9053N optionally with remote potentiometer
 LED indicators for operation and contact position
• Width KK 9053N: 22,5 mm
   Width BA 9053:     45 mm
                                                                                             ÃÒÂÅÐàÍÕ´

Voltage relay BA 9054, MK 9054

• According to IEC/EN 60 255, DIN VDE 0435-303
• to: monitor DC and AC Voltage
• Measuring ranges from 15 mV to  500 V
• High overload possible
• Input frequency up to 5 kHz
• with time delay
• LED indicators for operation and contact position
BA 9054 optionally with galvenic separated DC auxiliary supply
• MR 9054 optionally with remote potentiometer
BA 9054 as option with start-up delay 
BA 9054 as option with manual reset
• Width MK 9054N:  22,5 mm
• Width BA 9054         45 mm
                                                                                             ÃÒÂÅÐàÍÕ´

Phase monitor BD 9080

• According to IEC/EN 60 255, DIN VDE 0435-303
• Monitoring of
  - Under - and overvoltage

  - Asymmetry
  -
Phase sequence
• Release time adjustable between 0,1 ... 5 s
• One LED in each case for
  - Auxliiary voltage A1/A2
  - Overvoltage Umax
  - Undervoltage Umax

  - Asymmetry / Phase sequence / Power failure
  - Contact position
• Closed circuit operation
• Available opencircuit operation
• 2 changeover contacts
• Width 45 mm 

                                                                                             ÃÒÂÅÐàÍÕ´

Latching relay AD 8851

• According to IEC/EN 61 810-1
• Manual operation possible
• Contact position indication via control lever
max. 4 NC contacts, 4 NO contacts
• Width 45 mm  

                                                                                            ÃÒÂÅÐàÍÕ´

Insulation monitor IL 5881, SL 5881 varmeter

• According to IEC/EN 61 557
• For DC voltage systems up to 12 ... 280V
• Wide voltage range of measuring input UNDC 12 .... 280V
  ( on request DC 24 ... 500V with separate auxiliary supply
  Measuring range 20 ... 500 kΩ )
• Adjustable tripping value RAL of 5 ... 200 kΩ
• Selective ground fault indication for L+ and L- allows fast fault fitding
Without auxiliary supply
• De-energised on trip
• 2 changeover contacts 
• Automatic manual reset, programmable
• With test and resent buttons
• Connection for external test and resent button possible
 galvanic separated AC or DC auxiliary supplay available as option
• adjustable time delay as option
2 models available:
  IL 5881:     61 mm deep with terminals to the bottom to be
                   mounted in consumer units or industrial distribution

                   systems according to DIN 43 880
  SL 5881:     98 mm deep with terminals near to the top to be
                    mounted in cabinets with mounting plate and cable
                    ducts

• 35 mm width
                                                                                            ÃÒÂÅÐàÍÕ´

Under voltage relay IK9171 / IL9171 SK9171, SL9171, 3-phase

• According to IEC/EN 60 225, DIN VDE 0435-303
Devices available in 2 enclosure versions:
  I-model: depth 59 mm, with terminals at the bottom for

               Installation systems and industrial distribution
               systems according to DIN 43 880
  S-model: depth 98 mm, with terminals at the top for cabinets

            with mounting plate and cable duct

Monitoring of undervoltage in 3-phase system
• Also for single phase
• Without auxiliary supply
• Optionally for 3p 3w systems
• Independent of phase sequence
1 or 2 changeover contacts
 Optionlly fixed or settable response value
• As option with phase sequence detection
optionally with or without N
• Optionally with off-delay t1
• Optionally with on-delay t2                  
• Width:
• IK 9171, SK 9171 :      17,5 mm
• IL 9171, SL  9171 :        35 mm
                                                                                            ÃÒÂÅÐàÍÕ´