Phase sequence
relay BA 9041, AI 941 N
•
According to IEC 255, EN 60 255, VDE 0435 part 303
•
Detection pof wrong phase sequence
•
1 or 2 changeover contacts
•
Width 45 mm.
ÃÒÂÅÐàÍÕ´ |
|
Asymmetry
realy BA9042,AI942
•
According to IEC 255, VDE 0435 part 303
•
For nominal voltage from 3 AC 230 V to 500
•
Detection of
- voltage asymmetry
- wrong phase sequence
- phase failure
•
Detection of feedback voltage
•
BA 9042 optionally with ajdustable time delay
•
Closed circuit operation
• BA 9042 LED indicators for operation and state of cantacts
• 2 LED displays for power supply and state of contact
•
Width 45 mm
Standard Type: BA 9042 3 AC 400V 50/60 Hz
Article number: 0040770
stock item
- Output: 2 changeover contacts
- Nominal voltage UN: 3 AC 400
- Output: 2 changeover contacts
- Nominal voltage UN:
3 AC 400V
- Width: 45 mm
ÃÒÂÅÐàÍÕ´ |
|
Under voltage
realy BA9043,AA9943
•
According to IEC 255, VDE 0435 part 303
•
3-phase
•
For nominal voltage of 3 AC 100/57 to 690/400V
•
Measures arithmetic mean value
•
Adiustable operate and release value
•
For 3p3w or 3p4w systems
•
BA 9043 optionally with adiustable time delay
•
Closed circuit operation
•
LED indicator for operation and state of contact
• Insensitive to hermonics
• Frequency up to 400 Hz
•
Width 45 mm
ÃÒÂÅÐàÍÕ´ |
|
Thermistor
motor protection relay BA9038, AI938
•
According to DIN VDE 0660 part 302 ( pr EN 60 947-8 )
and part 303
•
1 input for PTC-resistors or bimetal contacts
•
Broken wire dtdection in sensor ciruit
•
Optionally with no voltage reclosing interlock
•
Closed circuit operation
•
1 or 2 changeover contacts
•
Width 45 mm
ÃÒÂÅÐàÍÕ´ |
|
Current relay
BA 9053, MK 9053
•
According to IEC 255, EN 60 255, VDE 0435 part 303
•
to: monitor DC and AC
•
Measuring ranges from 2 ma to 25 A
•
BA 9053 with galvanic separated DC auxiliary supplay
•
High overload possible
•
Input frequency up to 5 kHz
•
with time delay, up to max. 100 sec
•
BA 9053 optionally with 3 current ranges 0,1 to 25A
•
BA 9053 optionally with safe separation to IEC/EN 61 140
IEC/EN 60 947-1
• BA 9053 as option with start - up delay
•
BA 9053 as option with manual reset
•
MK 9053N optionally with remote potentiometer
• LED
indicators for operation and contact position
• Width KK 9053N: 22,5 mm
Width BA 9053:
45 mm
ÃÒÂÅÐàÍÕ´ |
|
Voltage relay
BA 9054, MK 9054
•
According to IEC/EN 60 255, DIN VDE 0435-303
•
to: monitor DC and AC Voltage
•
Measuring ranges from 15 mV to 500 V
•
High overload possible
•
Input frequency up to 5 kHz
•
with time delay
•
LED indicators for operation and contact position
•
BA 9054 optionally with galvenic separated DC auxiliary supply
•
MR 9054 optionally with remote potentiometer
•
BA 9054 as option with start-up delay
• BA 9054 as option with manual reset
• Width MK 9054N: 22,5 mm
•
Width BA 9054 45 mm
ÃÒÂÅÐàÍÕ´ |
|
Phase monitor
BD 9080
•
According to IEC/EN 60 255, DIN VDE 0435-303
•
Monitoring of
- Under - and overvoltage
- Asymmetry
- Phase sequence
•
Release time adjustable between 0,1 ... 5 s
•
One LED in each case for
- Auxliiary voltage A1/A2
- Overvoltage Umax
- Undervoltage Umax
- Asymmetry / Phase sequence / Power failure
- Contact position
•
Closed circuit operation
•
Available opencircuit operation
•
2 changeover contacts
•
Width 45 mm
ÃÒÂÅÐàÍÕ´ |
|
Latching relay
AD 8851
•
According to IEC/EN 61 810-1
•
Manual operation possible
•
Contact position indication via control lever
•
max. 4 NC contacts, 4 NO contacts
•
Width 45 mm
ÃÒÂÅÐàÍÕ´ |
|
Insulation
monitor IL 5881, SL 5881 varmeter
•
According to IEC/EN 61 557
•
For DC voltage systems up to 12 ... 280V
•
Wide voltage range of measuring input UNDC 12 .... 280V
( on request DC 24 ... 500V with
separate auxiliary supply
Measuring range 20 ... 500 kΩ )
•
Adjustable tripping value RAL of 5 ... 200 kΩ
•
Selective ground fault indication for L+ and L- allows fast fault
fitding
•
Without auxiliary supply
•
De-energised on trip
•
2 changeover contacts
• Automatic manual reset, programmable
• With test and resent buttons
•
Connection for external test and resent button possible
• galvanic
separated AC or DC auxiliary supplay available as option
• adjustable time delay as option
•
2 models available:
IL
5881: 61 mm deep with terminals to the
bottom to be
mounted in consumer units or industrial distribution
systems according to DIN 43 880
SL 5881: 98 mm deep with terminals
near to the top to be
mounted in cabinets with mounting plate and cable
ducts
• 35 mm width
ÃÒÂÅÐàÍÕ´ |
|
Under voltage
relay IK9171 / IL9171 SK9171, SL9171, 3-phase
•
According to IEC/EN 60 225, DIN VDE 0435-303
•
Devices available in 2 enclosure versions:
I-model: depth 59 mm, with terminals at the bottom for
Installation systems and industrial distribution
systems according to DIN 43 880
S-model: depth 98 mm, with terminals at the top for cabinets
with mounting plate and cable duct
•
Monitoring of undervoltage in 3-phase system
•
Also for single phase
•
Without auxiliary supply
• Optionally for 3p 3w systems
• Independent of phase sequence
• 1 or 2
changeover contacts
• Optionlly
fixed or settable response value
• As option with phase sequence detection
•
optionally with or without N
•
Optionally with off-delay t1
•
Optionally with on-delay t2
• Width:
• IK
9171, SK 9171 : 17,5 mm
• IL
9171, SL
9171
: 35 mm